This is the Owners Manual and Calibration guide for all Palmscales. For advanced Palmscale information, see
Palmscale 6.0 Advanced Programming/Repair
. *If your PS6 will not charge it's battery, please click
HERE
SPECIAL TROUBLESHOOTING NOTE:
If your PS6 won't turn on (the screen is entirely blank) and
you've tried recharging the scale without any change, please remove and
then properly re-install the battery. That will usually fix the problem.
Although this has only happened a couple of times to date, it is possible that
if certain scales are seriously shaken (usually during shipping) for the metal
battery springs to move slightly and stop making proper contact with the
battery.
PALMSCALE 6.0
OPERATION AND CALIBRATION INSTRUCTIONS
This scale is very easy to
operate. However, there are certain caring and operation instructions you should
read before your first use.
We know taking the time to read these instructions is time consuming, but this
scale is a precision instrument and must be handled with the utmost care.
IMPORTANT:
1)
To open the scale, slide the switch on the
right side of the scale
2)
Do
not get the scale wet or hot and do not operate on any wet or hot surface. To
clean the scale, wipe the surface with a clean damp cloth or mild non-abrasive
cleaner. Do not use any abrasive cleaner because it may damage the finish.
3)
Do not overload the scale. That is,
do not place anything that weighs more than 250 grams on the platform. You
may permanently damage the load cell.
4)
Handle the scale with care. This is a precision instrument and should never be
dropped or otherwise mishandled.
5)
SEQ CHAPTER \h \r 1Place
the item to be weighed on the platform, after the stable weight is displayed
remove the item immediately. This will prolong the longevity and accuracy of
this weighing instrument.
6)
Do
not leave anything on the scale when not is use.
7)
If
the scale is excessively cold or hot, allow the scale to warm up to normal room
temperature for at least 1 hour prior to use.
8)
Do not operate a cell phone or cordless phone within 10 feet of the scale****
It may temporarily cause the scale to malfunction.
9)
Only recharge the scale when the batteries are low.
When the display reads “Lo”, please recharge the battery using the charging
station.
10)
In
the unlikely event that the scale permanently “locks up” or shows ERR, visit
www.myweigh.com for Advanced Troubleshooting.
11)
If
your scale should require recalibration, please refer to the calibration guide
on the next page.
12)
Please keep your scale in it’s protective pouch when not in use.
INSTRUCTION MANUAL
1.
Do
not put anything on the scale tray before you turn it on.
2.
Turn
the scale on by pressing the POWER key.
After 2 seconds, the display will read “0.0g”.
3.
Always allow the scale to warm up for at least 30 seconds before weighing for
accuracy & stability.
4.
Place the item to be weighed on the center of the platform and read the value on
the display.
5.
TARE Function: If you need to weigh
loose items or anything in a container or tray you should: 1) Turn the scale ON.
2) Place the empty container or tray on the platform. 3) Press the TARE button.
4) Place the items to be weighed into the container / tray. 5) The exact weight
of the items will show. (use your tweezers to handle all gems)
6.
The
scale has an Auto-Off feature that turns off the scale after lapses of
non-activity. If the scale is in a room with wind or air movement, it may sense
the pressure of the air and not auto-off. In this case simply press POWER
to turn the scale off manually.
7.
MODE Function: This scale has the
ability to weigh in grams or ounces. The selection is done by simply pressing
the MODE key once the scale is on (Look for the g, oz, ozt, dwt or ct on the top
of the display).
8.
BACKLIGHT: The backlight will be
automatically turned on whenever the reading change is more than 0.5g. You can
also turn it on manually by pressing the LIGHT key.
The backlight will automatically turn off after a few seconds.
9.
Battery Charging:
To prolong battery life only charge the scale
when the batteries are low. Attach the AC adaptor to the docking station (at
the rear). Plug the power supply into an AC outlet. The GREEN LED comes on
indicating that the connection is normal. Place the scale in the charging
station with the front cover facing up. The RED LED comes on indicating that the
battery is charging. When the battery is fully charged, the GREEN LED will come
on again and the scale can be removed for use.
10.
Temperature: The recommended
operating temperature is 64-82F (16-25C). Please only operate the scale at
recommended temperatures.
CAPACITY OF SCALE: 250G ACCURACY: +/- 0.1g
CALIBRATION INSTRUCTIONS
THIS SCALE IS ACCURATE
WITHIN 0.1g, only calibrate if your readings are inaccurate beyond 0.1g. Allow
your scale to warm up for several seconds before calibration. Always move your
hands very gently during calibration as to not cause vibrations or air movement.
1.
PLACE THE SCALE ON A FLAT SURFACE THAT HAS NO VIBRATIONS AND MAKE SURE THERE IS
ABSOLUTELY NO AIR MOVEMENT. (SURFACE MUST BE EXTREMELY STABLE).
2.
TURN
THE SCALE OFF AND CLEAR THE PLATFORM (MAKE SURE NOTHING IS ON THE
PLATFORM NOT EVEN THE PLASTIC TRAY).
3.
TURN
THE SCALE ON BY PRESSING the POWER key.
4.
WHEN
THE DISPLAY SHOWS 0.0, WAIT 5 SECONDS AND THEN PLACE A 100 GRAM WEIGHT ON THE
CENTER OF THE PLATFORM.
5.
WAIT
FOR THE DISPLAY TO STABILIZE, THEN PRESS AND HOLD THE MODE KEY FOR 10
SECONDS. THE DISPLAY WILL FLASH 100.0 TWICE, (THIS WILL TAKE ABOUT 7
SECONDS, CONTINUE TO HOLD THE KEY FOR AN EXTRA COUPLE OF SECONDS AFTER IT HAS
STOPPED FLASHING)
6.
RELEASE THE MODE KEY AND REMOVE THE WEIGHT FROM THE PLATFORM.
CALIBRATION IS COMPLETE
IF THE READINGS ARE
INACCURATE, PERFORM CALIBRATION AGAIN. IF YOUR SCALE WILL NOT PROPERLY CALIBRATE
OR SHOWS “ERR” PLEASE VISIT OUR WEBSITE FOR ADVANCED CALIBRATION &
TROUBLESHOOTING INSTRUCTIONS
BATTERY INSTRUCTIONS
ONLY RECHARGE THE SCALE
WHEN THE BATTERY IS LOW. THIS WILL PROLONG THE NiMH BATTERY LIFE.
CAUTION
DANGER OF EXPLOSION IF
BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME TYPE OF RECHARGEABLE
BATTERIES. INSTALLATION OF NON-RECHARGEABLE BATTERIES COULD CAUSE AN EXPLOSION
IF YOU PLACE THE SCALE IN THE DOCKING STATION (ATTEMPTING TO CHARGE A
NON-RECHARGEABLE BATTERY CAN CAUSE AN EXPLOSION OR FIRE)
ADVANCED STABILITY
FEATURE (ASF)
This scale has a stability
indicator, the letter “S” in the top left corner of the screen. Whenever the
letter “S” is displayed that means the displayed weight is stable.
TOOLS (ONBOARD)
The PALMSCALE 6.0 has
on-board tools for handling gems and other loose materials. You can find an
on-board scoop and tweezers on the bottom of the scale.
EXPANSION TRAY AND BOWL
FOR LOOSE ITEMS
There is a platform
expansion tray and bowl included in the box. They are designed to fit on top of
the platform. Simply install the tray or bowl and then turn the scale ON.
***IF YOU HAVE
QUESTIONS OR NEED ASSISTANCE PLEASE VISIT
WWW.MYWEIGH.COM WE CAN USUALLY HELP YOU FIX YOUR SCALE VERY QUICKLY SO
PLEASE CONTACT US IF YOU NEED ANY HELP. IF YOU WANT TO LEARN MORE ABOUT YOUR
SCALE OR NEED REPLACEMENT PARTS, VISIT
WWW.MYWEIGH.COM
There is an advanced
troubleshooting and programming guide available online for this scale at our
website.
Words of Advice:
The PALMSCALE 6.0 is
undoubtedly one of the coolest pocket scales ever created and the first of it’s
kind. Please remember that this is a precision instrument. It is essential that
you never drop, shake or otherwise mishandle this instrument. Electronic
precision scales use delicate sensors that can easily be damaged if the scale is
excessively shocked, dropped or overload. An abused scale will only work until
it’s sensors are damaged, but a well kept scale will last for your lifetime.
Please be good to your
PALMSCALE !
My Weigh is the Best
Weigh !
|