This is the Owners Manual and Calibration guide for the Tempest. The
Tempest uses a special program - to do an advanced calibration for the
Tempest please see the bottom of this page or click here Low Batteries & bad battery
connections are the #1 cause of scale malfunction and inaccuracy! We test all of our scale returns from consumers. Fully
60% of consumer returns are battery related problems. This sounds silly but it's true!
A scale will perform slowly, or read inaccurately when it has low batteries. Please replace the batteries often (and only use good quality batteries). We include good quality batteries with all of our scales but batteries can run low in storage.
If your scale simply won't turn on while on Battery power, this is
often caused by loose battery connections. Battery prongs (terminals) are
made of metal. They must be making good contact with your batteries in order for
the scale to power on. You can use a paperclip to slightly bend the
battery prongs to make them have a better connection. Also some poorly designed
batteries have recessed or partially obstructed battery terminals. This may
cause your prongs to be touching the plastic housing of the battery instead of
the metal battery terminal.
IMPORTANT
AMENDED CALIBRATION INSTRUCTIONS FOR THE TEMPEST 500
Amended Tempest 500 Calibration Instructions
1. PLACE THE SCALE ON A FLAT SURFACE THAT HAS NO VIBRATIONS AND MAKE SURE
THERE IS ABSOLUTELY NO AIR MOVEMENT. (SURFACE MUST BE EXTREMELY STABLE).
2. TURN THE SCALE OFF AND CLEAR THE PLATFORM (MAKE SURE NOTHING IS ON THE
PLATFORM NOT EVEN THE PLASTIC TRAY).
3. TURN THE SCALE ON BY PRESSING THE ON KEY. WHEN THE DISPLAY SHOWS 0.0, WAIT
5 SECONDS.
4. PRESS AND HOLD THE ON KEY FOR 3 SECONDS UNTIL IT SHOWS "0", THEN RELEASE
THE KEY.
5. IT WILL THEN SHOW "100". IF THE NUMBER IS NOT "100" (e.g. 500), USE THE
TARE BUTTON TO ADJUST IT TO "100". THE UNIT "g" WILL KEEP FLASHING. PLACE A 100
GRAM WEIGHT ON THE CENTER OF THE PLATFORM AND WAIT FOR 5 SECONDS.
6. THE SCALE WILL SHOW "100.0" AND THE UNIT "g" WILL STOP FLASHING AFTER THE
CALIBRATION IS COMPLETE.
TEMPEST 250
OPERATION AND CALIBRATION INSTRUCTIONS
This scale is very easy to
operate. However, there are certain caring and operation instructions you should
read before your first use
We know taking the time to read these instructions is time consuming, but this
scale is a precision instrument and must be handled with the utmost care.
IMPORTANT:
1)
To open the scale, simply lift up
the cover.
2)
Always empty the tray/platform
before turning the power on (clear the platform before turning on).
3)
Do not get the scale wet or hot
and do not operate on any wet or hot surface. To clean the scale, wipe the
surface with a clean damp cloth or mild non-abrasive cleaner. Do not use any
abrasive cleaner because it may damage the finish.
4)
Do not overload the scale.
That is, do not place anything that weighs more than 250 grams on the platform.
You may permanently damage the load cell.
5)
Handle the scale with care. This
is a precision instrument and should never be dropped or otherwise mishandled.
6)
Do not leave anything on the
scale when not is use.
7)
If the scale is excessively cold
or hot, allow the scale to warm up to normal room temperature for at least 1
hour prior to use.
8)
Do not operate a cell phone or
cordless phone within 10 feet of the scale****
It may temporarily cause the scale to malfunction.
9)
If the scale ever reads “Lo” or
weighs very slowly, please replace the batteries.
10)
In the unlikely event that the
scale permanently “locks up” or shows ERR, visit
www.myweigh.com for Advanced Troubleshooting.
11)
If your scale should require
recalibration, please refer to the calibration guide on the next page.
12)
Please keep your scale in it’s
protective pouch when not in use.
INSTRUCTION MANUAL
1.
Do not put anything on the scale
tray before you turn it on.
2.
Turn the scale on by pressing .
After 2 seconds, the display will read “0.0g”.
3.
Always allow the scale to warm up
for at least 30 seconds before weighing for accuracy & stability.
4.
Place the item to be weighed on
the center of the platform and read the value on the display.
5.
TARE Function:
If you need to weigh loose items or anything in a container or tray you should:
1) Turn the scale ON. 2) Place the empty container or tray on the platform. 3)
Press the TARE button. 4) Place the items to be weighed into the container /
tray. 5) The exact weight of the items will show. (use your tweezers to handle
all gems)
6.
The scale has an Auto-Off feature
that turns off the scale after lapses of non-activity. If the scale is in a room
with wind or air movement, it may sense the pressure of the air and not
auto-off. In this case simply press
to turn the scale off manually.
7.
MODE Function:
This scale has the ability to weigh in grams or ounces. The selection is done by
simply pressing the MODE key once the scale is on (Look for the g, oz, ozt, dwt
or ct on the top of the display).
8.
BACKLIGHT:
The backlight will be automatically turned on whenever the reading change is
more than 0.5g. You can also turn it on manually by pressing the key.
The backlight will automatically turn off after a few seconds. If you want to
save the battery life, you may turn off the backlight power using the manual
backlight-disable switch on the bottom of the scale.
9.
Temperature:
The recommended operating temperature is 64-82F (16-25C). Please only operate
the scale at recommended temperatures.
CAPACITY OF SCALE: 250G ACCURACY: +/- 0.1g
CALIBRATION INSTRUCTIONS
THIS SCALE IS ACCURATE
WITHIN 0.1g, only calibrate if your readings are inaccurate beyond 0.1g. Allow
your scale to warm up for several seconds before calibration. Always move your
hands very gently during calibration as to not cause vibrations or air movement.
1.
PLACE THE SCALE ON A FLAT SURFACE
THAT HAS NO VIBRATIONS AND MAKE SURE THERE IS ABSOLUTELY NO AIR MOVEMENT.
(SURFACE MUST BE EXTREMELY STABLE).
2.
TURN THE SCALE OFF AND CLEAR THE
PLATFORM (MAKE SURE NOTHING IS ON THE PLATFORM NOT EVEN THE
PLASTIC TRAY).
3.
TURN THE SCALE ON BY PRESSING .
4.
WHEN THE DISPLAY SHOWS 0.0, WAIT
5 SECONDS AND THEN PLACE A 100 GRAM WEIGHT ON THE CENTER OF THE PLATFORM.
5.
WAIT FOR THE DISPLAY TO
STABILIZE, THEN PRESS AND HOLD THE MODE KEY FOR 10 SECONDS. THE DISPLAY
WILL FLASH 100.0 TWICE, (THIS WILL TAKE ABOUT 7 SECONDS, CONTINUE TO HOLD THE
KEY FOR AN EXTRA COUPLE OF SECONDS AFTER IT HAS STOPPED FLASHING)
6.
RELEASE THE MODE KEY AND
REMOVE THE WEIGHT FROM THE PLATFORM. CALIBRATION IS COMPLETE
IF THE READINGS ARE
INACCURATE, PERFORM CALIBRATION AGAIN. IF YOUR SCALE WILL NOT PROPERLY CALIBRATE
OR SHOWS “ERR” PLEASE VISIT OUR WEBSITE FOR ADVANCED CALIBRATION &
TROUBLESHOOTING INSTRUCTIONS
BATTERY INSTRUCTIONS
USE TWO AAA BATTERIES.
PLEASE MAKE SURE THE POLARITY IS CORRECT WHEN INSTALLING NEW BATTERIES. LOW
BATTERIES ARE THE #1 CAUSE OF SCALE MALFUCTION SO BE SURE YOUR BATTERIES ARE
GOOD.
ADVANCED STABILITY
FEATURE (ASF)
This scale has a stability
indicator, the letter “S” in the top left corner of the screen. Whenever the
letter “S” is displayed that means the displayed weight is stable.
TOOLS
The Tempest 250 has tools
for handling gems and other loose materials. You can find a scoop and tweezers
inside the carrying pouch.
EXPANSION TRAY AND BOWL
FOR LOOSE ITEMS
There is a platform
expansion tray and bowl included in the box. They are designed to fit on top of
the platform. Simply install the tray or bowl and then turn the scale ON.
***IF YOU HAVE
QUESTIONS OR NEED ASSISTANCE PLEASE VISIT
WWW.MYWEIGH.COM WE CAN USUALLY HELP YOU FIX YOUR SCALE VERY QUICKLY SO
PLEASE CONTACT US IF YOU NEED ANY HELP. IF YOU WANT TO LEARN MORE ABOUT YOUR
SCALE OR NEED REPLACEMENT PARTS, VISIT
WWW.MYWEIGH.COM
There is an advanced
troubleshooting and programming guide available online for this scale at our
website.
Words of Advice:
The Tempest 250 is
undoubtedly one of the coolest pocket scales ever created and the first of it’s
kind. Please remember that this is a precision instrument. It is essential that
you never drop, shake or otherwise mishandle this instrument. Electronic
precision scales use delicate sensors that can easily be damaged if the scale is
excessively shocked, dropped or overload. An abused scale will only work until
it’s sensors are damaged, but a well kept scale will last for your lifetime.
Please be good to your
Tempest !
My Weigh is the Best
Weigh !
**Procedure of full calibration for
Tempest**
In Programming mode pressing the MODE key will increase the blinking number,
Pressing the TARE key will shift the blinking number to the next line. If you
press the MODE key it simply increases the number. So if the blinking number is
1 and you press the MODE key, it will increase that number to 2. The TARE key
shifts the blinking digit to the next line.
1.
Turn on the scale and wait for 0.0g.
2.
Press and hold TARE for 5 sec.
3.
Page 1 = 7115. If it does not show the correct number, use TARE (shift
digit) and MODE (adjust value) to change it. Press BACKLIGHT.
4.
Page 2 = 8295. If it does not show the correct number, use TARE (shift
digit) and MODE (adjust value) to change it. Press BACKLIGHT .
5.
Page 3 = XXXX, Do not change it. Press BACKLIGHT.
6.
When you see a steady 3 digit (or 4 digit) number ("S" icon must be
turned on). Press TARE shortly and release. You will see the version number e.g.
"E2.41" or "F2.41" when you press the TARE button.
7.
Put the 100g standard weight on the platform and wait until the 4 digit
number is steady (check "S" icon). Press BACKLIGHT. It’ll show “2500”.
8.
Use TARE (shift digit) and MODE (adjust value) to change the display from
"2500" to "1000". Press BACKLIGHT.
9.
It'll show "OFF" and the process is complete.
|